CAT LAB · SINGLE-PHASE THERMAL SCREENING

Heat Exchanger

Size the conductance for a target duty, or rate a supplied UA. Inspect both outlet temperatures, terminal approaches, and the property basis.

Draft · calculation not run

Equal-capacity synthetic example loaded. Review its assumptions, then calculate.

Preparing browser storage…. Save a named calculation below to keep revisions. Compatible unit changes preserve the entered quantity.

Saved calculations

Save a named case in this browser, then select it directly in Analysis Workspace. JSON remains an optional backup and a way to move work to another device.

Working case: Synthetic equal-capacity example

This working case has no selected saved identity. Saving creates a new case.

Reopen a saved calculation

Selecting a case or revision does not change the working inputs. Review the replacement before opening it.

1 · Define the case

Two steady, nonreacting streams with constant Cp. No boiling, condensation, ambient heat loss, or pass correction is modeled.

2 · Specify the streams

Use source-marked properties for the intended temperature range.

Hot stream

Temperature on entry to the exchanger.

Constant mass-specific heat capacity. No property is inferred from the phase.

Name the reference, measurement, or explicit assumption and its conditions.

Hot stream Cp applicability range

Supply both temperature limits, or leave both blank. No range is invented.

Check both inlet and calculated outlet against this supplied interval.

Cold stream

Temperature on entry to the exchanger.

Constant mass-specific heat capacity. No property is inferred from the phase.

Name the reference, measurement, or explicit assumption and its conditions.

Cold stream Cp applicability range

Supply both temperature limits, or leave both blank. No range is invented.

Check both inlet and calculated outlet against this supplied interval.

3 · Set the thermal requirement

Overall heat-transfer conductance, not a heat-transfer coefficient. Zero UA represents no heat transfer.

Optional area estimate and U basis

A supplied U is required for area. Missing or invalid U must not remove independent duty and outlet results.

Use a reference, measurement, or explicit screening assumption. No U is inferred from the fluid.

For example, outside tube area. The calculated area uses this same basis.

Record fouling treatment, property assumptions, and unresolved limitations. Fouling is not predicted here.

Heat duty · hot to cold—
Supplied conductance UA—
Hot stream outlet—
Cold stream outlet—

Synthetic equal-capacity example

Draft · calculation not run

Input / sourceOriginal entryUnit / state
Calculation moderating
Arrangementcounterflow
Hot stream phaseliquid
Cold stream phaseliquid
Hot mass flow1kg/s
Cold mass flow1kg/s
Hot specific heat capacity1kJ/(kg·K)
Cold specific heat capacity1kJ/(kg·K)
Hot inlet temperature100°C
Cold inlet temperature20°C
Target heat duty40kW · inactive in this mode
Supplied UA1kW/K
Supplied overall coefficient U500W/(m²·K)
Hot Cp minimum temperatureNot supplied°C
Hot Cp maximum temperatureNot supplied°C
Cold Cp minimum temperatureNot supplied°C
Cold Cp maximum temperatureNot supplied°C
Hot Cp sourceSynthetic constant-Cp assumption for an analytical example; no real fluid property claim.
Cold Cp sourceSynthetic constant-Cp assumption for an analytical example; no real fluid property claim.
U sourceSynthetic U assumption, not an equipment correlation.
U area basisDeclared demonstration heat-transfer surface
U conventiondesign
Assumptions and fouling notesIllustrative arithmetic only. Phase and Cp temperature applicability are not established. No fouling calculation is included.

Draft · calculation not run

Review the two streams and the selected sizing or rating input, then choose Calculate. A saved or imported answer is not current calculation evidence.

The equal-capacity synthetic example uses two 1 kW/K streams at 100 °C and 20 °C. In counterflow with UA = 1 kW/K, the analytical reference is 40 kW, two 60 °C outlets, and 2 m² for the stated U. These are demonstration values, not measurements.

Model scope and assumptions
  • Two nonreacting streams remain in their declared single phases throughout the exchanger.
  • Steady state; constant mass-specific heat capacities and constant overall conductance; no ambient heat loss or shaft work.
  • Only ideal parallel flow and counterflow are supported. No pass correction, boiling, condensation, or maldistribution model.
  • U is supplied with its source, area basis, and clean/design convention; no film coefficient or fouling prediction is made.
  • Pressure loss, mechanical design, material compatibility, controls, and equipment qualification are outside this model.

This result supports preliminary thermal screening. It does not establish mechanical design, pressure rating, procurement readiness, or experimentally validated equipment performance.

Scientific references

Keep the record and continue

Export the original inputs, sources, model version, and current calculation when available. Imported cached answers are historical until recomputed.

Open Analysis Workspace →

Save a named calculation above, then select it directly in the workspace alongside balance and bed records. JSON is optional for backup or transfer between devices.

Import a heat-exchanger case

Import validates the record, then asks you to review the replacement. Save the current calculation first if you want to keep both.